1 #ifndef __POWERLOGIC_POWERMETER_IDL__ 2 #define __POWERLOGIC_POWERMETER_IDL__ 5 #include <NumericSensor.idl> 6 #include <ModbusDevice.idl> 103 valueobject SetupChangedEvent extends
idl.Event {
109 valueobject ErrorStatusChangedEvent extends
idl.Event {
140 void resetAllMinMaxValues();
145 void clearAllEnergyAccumulators();
Structured object for line to line sensors including average.
Definition: PowerLogicPowerMeter.idl:30
MinMaxReading l3l1
L3-L1.
Definition: PowerLogicPowerMeter.idl:33
MinMaxReading l1
L1-L2.
Definition: PowerLogicPowerMeter.idl:39
A sensor with numeric readings.
Definition: NumericSensor.idl:12
Structured object for line to neutral sensors including neutral and average.
Definition: PowerLogicPowerMeter.idl:21
ErrorStatus newStatus
Error status flags after change.
Definition: PowerLogicPowerMeter.idl:111
L2N_plain_total apparentPower
apparent power sensor (L1, L2, L3, total)
Definition: PowerLogicPowerMeter.idl:75
sensors::NumericSensor_4_0_1 activeEnergy
real energy sensor (total)
Definition: PowerLogicPowerMeter.idl:77
sensors::NumericSensor_4_0_1 average
average
Definition: PowerLogicPowerMeter.idl:26
L2L_Avg voltageL2L
line to line voltage sensors (L1-L2, L2-L3, L3-L1, 3P average)
Definition: PowerLogicPowerMeter.idl:70
MinMaxReading l3
L3.
Definition: PowerLogicPowerMeter.idl:24
L2N thdVoltageL2N
total harmonic distortion sensors for voltage (L1-N, L2-N, L3-N)
Definition: PowerLogicPowerMeter.idl:82
int systemType
wiring identifier
Definition: PowerLogicPowerMeter.idl:87
L2N_N_Avg current
current sensors (L1, L2, L3, N, 3P average)
Definition: PowerLogicPowerMeter.idl:69
sensors::NumericSensor_4_0_1 average
average
Definition: PowerLogicPowerMeter.idl:42
MinMaxReading total
total
Definition: PowerLogicPowerMeter.idl:64
boolean cL2saturation
current L2 saturation
Definition: PowerLogicPowerMeter.idl:97
MinMaxReading l3
L3.
Definition: PowerLogicPowerMeter.idl:49
sensors::NumericSensor_4_0_1 apparentEnergy
apparent energy sensor (total)
Definition: PowerLogicPowerMeter.idl:79
Structured object for line to neutral voltage sensors.
Definition: PowerLogicPowerMeter.idl:46
sensors::NumericSensor_4_0_1 frequency
frequency sensor
Definition: PowerLogicPowerMeter.idl:72
Definition: ModbusDevice.idl:4
L2N_plain_total activePower
real power sensor (L1, L2, L3, total)
Definition: PowerLogicPowerMeter.idl:73
Error status flags.
Definition: PowerLogicPowerMeter.idl:92
sensors::NumericSensor_4_0_1 max
maximum reading
Definition: PowerLogicPowerMeter.idl:16
MinMaxReading l1
L1.
Definition: PowerLogicPowerMeter.idl:47
L2N thdCurrent
total harmonic distortion sensors for current (L1, L2, L3)
Definition: PowerLogicPowerMeter.idl:80
MinMaxReading l1
L1.
Definition: PowerLogicPowerMeter.idl:22
sensors::NumericSensor_4_0_1 l1
L1.
Definition: PowerLogicPowerMeter.idl:61
Basic IDL definitions.
Definition: Event.idl:6
MinMaxReading l2l3
L2-L3.
Definition: PowerLogicPowerMeter.idl:32
Setup newSetup
Setup after change.
Definition: PowerLogicPowerMeter.idl:105
L2N_plain_total reactivePower
reactive power sensor (L1, L2, L3, total)
Definition: PowerLogicPowerMeter.idl:74
L2N_Avg voltageL2N
line to neutral voltage sensors (L1-N, L2-N, L3-N, 3P average)
Definition: PowerLogicPowerMeter.idl:71
Structured object grouping minimum, maximum and current sensor.
Definition: PowerLogicPowerMeter.idl:14
Structured object for line to neutral voltage sensors.
Definition: PowerLogicPowerMeter.idl:60
boolean vL1saturation
voltage L1 saturation
Definition: PowerLogicPowerMeter.idl:93
int displayMode
IEC / IEEE units.
Definition: PowerLogicPowerMeter.idl:88
MinMaxReading l3
L3-L1.
Definition: PowerLogicPowerMeter.idl:41
sensors::NumericSensor_4_0_1 l2
L2.
Definition: PowerLogicPowerMeter.idl:62
MinMaxReading l1l2
L1-L2.
Definition: PowerLogicPowerMeter.idl:54
MinMaxReading l2
L2.
Definition: PowerLogicPowerMeter.idl:23
boolean cL3saturation
current L3 saturation
Definition: PowerLogicPowerMeter.idl:98
sensors::NumericSensor_4_0_1 min
minimum reading
Definition: PowerLogicPowerMeter.idl:15
Sensors Model.
Definition: AccumulatingNumericSensor.idl:8
boolean freqInvalid
frequency invalid
Definition: PowerLogicPowerMeter.idl:99
PowerLogic Power Meter setup.
Definition: PowerLogicPowerMeter.idl:86
MinMaxReading l2
L2.
Definition: PowerLogicPowerMeter.idl:48
Definition: PowerLogicConfig.idl:6
boolean vL2saturation
voltage L2 saturation
Definition: PowerLogicPowerMeter.idl:94
boolean vL3saturation
voltage L3 saturation
Definition: PowerLogicPowerMeter.idl:95
sensors::NumericSensor_4_0_1 reactiveEnergy
reactive energy sensor (total)
Definition: PowerLogicPowerMeter.idl:78
PowerLogic Power Meter Interface.
Definition: PowerLogicPowerMeter.idl:11
Sensors.
Definition: PowerLogicPowerMeter.idl:68
sensors::NumericSensor_4_0_1 l3
L3.
Definition: PowerLogicPowerMeter.idl:63
MinMaxReading l3l1
L3-L1.
Definition: PowerLogicPowerMeter.idl:56
MinMaxReading l2
L2-L3.
Definition: PowerLogicPowerMeter.idl:40
boolean cL1saturation
current L1 saturation
Definition: PowerLogicPowerMeter.idl:96
sensors::NumericSensor_4_0_1 average
average
Definition: PowerLogicPowerMeter.idl:34
Structured object for line to line sensors.
Definition: PowerLogicPowerMeter.idl:53
MinMaxReading l1l2
L1-L2.
Definition: PowerLogicPowerMeter.idl:31
MinMaxReading l2l3
L2-L3.
Definition: PowerLogicPowerMeter.idl:55
sensors::NumericSensor_4_0_1 reading
current reading
Definition: PowerLogicPowerMeter.idl:17
sensors::NumericSensor_4_0_1 n
neutral
Definition: PowerLogicPowerMeter.idl:25
MinMaxReading powerFactor
power factor sensor (total)
Definition: PowerLogicPowerMeter.idl:76
Structured object for line to neutral sensors including average.
Definition: PowerLogicPowerMeter.idl:38
L2L thdVoltageL2L
total harmonic distortion sensors for voltage (L1-L2, L2-L3, L3-L1)
Definition: PowerLogicPowerMeter.idl:81